Numerical investigation of losses in a double-suction multistage centrifugal pump and its mitigation using baffle plates

Shamsuddeen, Mohamed Murshid and Kim, Sung and Shahzer, Mohammad Abu and Ma, Sang-Bum and Kim, Jin-Hyuk (2022) Numerical investigation of losses in a double-suction multistage centrifugal pump and its mitigation using baffle plates. Frontiers in Energy Research, 10. ISSN 2296-598X

[thumbnail of pubmed-zip/versions/1/package-entries/fenrg-10-969706/fenrg-10-969706.pdf] Text
pubmed-zip/versions/1/package-entries/fenrg-10-969706/fenrg-10-969706.pdf - Published Version

Download (4MB)

Abstract

The flow in a double-suction twin-volute five-stage centrifugal pump is studied numerically using Computational Fluid Dynamics (CFD) calculations. The pump performance at various flow rates obtained numerically are compared with the theoretically results. The deterioration in pump performance at various flow rates were investigated to find the losses associated with the design of the pump components. The stage-wise performance analysis revealed the hydraulic losses associated with the second-stage impeller due to highly swirled flow exiting from the first stage twin-volute. The fluid exiting the twin-volute have a high circumferential velocity than its radial component leading to a high pre-swirl at the inlet of stage 2 impeller. In order to regulate the high pre-swirl, baffle plates were installed at the exit of the twin-volute. Three baffle plate configurations were studied and their effects on the pump performances were compared. The vertical configuration improved the pump efficiency by 1.36% and head by 6.04% while the horizontal configuration improved them by 2.42% and 5.96% respectively. The 4-plate baffle configuration improved the pump performance by only a small margin. The installation of the baffle plates also improved the stage performances in both design and off-design conditions. The horizontally installed baffle plates were then tested at various angles. The plates installed at 300° clock-wise increased the pump head by 9.08% and efficiency by 3.87%. A comprehensive analysis of the flow physics inside the pump are also presented.

Item Type: Article
Subjects: South Asian Archive > Energy
Depositing User: Unnamed user with email support@southasianarchive.com
Date Deposited: 08 May 2023 06:35
Last Modified: 22 Jun 2024 09:18